logo
Contacte-nos

Pessoa de Contato : Phoebe Yu

Número de telefone : 8618620854039

Whatsapp : +8618620854039

Free call

JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling

Quantidade de ordem mínima : 1 Preço : USD12900 - USD14300
Detalhes da embalagem : Embalagem personalizada Tempo de entrega : 90-120 dias de trabalho
Termos de pagamento : T/T, Western Union Habilidade da fonte : 5PCS/90-120 dias
Lugar de origem: China Marca: JINSP
Certificação: ISO9001 Número do modelo: SR100Q

Informação detalhada

Faixa espectrual: 200nm - 1100nm Pixels eficazes: 1024*122
Eficiência Qutuam: QE92% peak@650nm, 83%@232nm Snr: 1000: 1

Descrição de produto

92% High Quantum Efficiency CCD Modular Fiber Optic Spectrometer

Designed for researchers and engineers, the JINSP SR100Q Spectrometer combines high-resolution optics with cutting-edge sensor technology. The built-in Hamamatsu CCD with TE cooling minimizes thermal noise, enabling precise detection of weak light signals. With peak QE reaching 92%, users can trust the SR100Q for accurate spectral data across UV, VIS, and NIR ranges.

 

This spectrometer is particularly well-suited for laser spectral measurement, allowing real-time tracking of wavelength, intensity, FWHM, and multi-peak analysis. It also supports film thickness measurement via reflective or absorptive spectral methods, providing non-destructive testing solutions for semiconductors and optical coatings.

 

With its robust FPGA processing and intuitive operation, the SR100Q is a reliable tool for advancing scientific and industrial applications.

Product Parameters:

Detector Chip Type Back-illuminated TE-cooled Hamamatsu S7031
Effective Pixel 1024*122
Pixel Size 24*24μm
Sensing Area 24.576*2.928mm
Optical
Parameters
Optical Design F/4 cross-type
Numerical Aperture 0.13
Focal Length 100mm
Entrance Slit Width 10μm,25μm,50μm,100μm,200μm
(customizable)
Fiber Interface SMA905,free space
Electrical
Parameters
Integration Time 8ms-3600s
Data Output Interface USB3.0,RS232,RS485,20pin connector
ADC Bit Depth 16-bit
Power Supply 5V
Operating Current <3.5A
Physical
Parameters
Operating Temperature 10℃~40℃
Storage Temperature -20℃~60℃
Operating Humidity <90%RH (no condensation)
Dimensions 180mm*120mm*50mm
Weight 1.2kg

 

List of Product Models:

Model Spectral Range(nm) Resolution(nm) Slit(μm)
SR100Q-G21

SR100Q-G22
200~950

350~1100
6.8 200
2.2 50
1.5 25
1.0 10
SR100Q-G23

SR100Q-G24
200~775

350~925
1.6 50
1.0 25
0.7 10
SR100Q-G25 532~690(4400cm-1*)* 13cm-1 50
SR100Q-G26 638~800(3200cm-1)* 10cm-1 25
SR100Q-G27 785~1050(3200cm-1)* 11cm-1 50

 

Technical Characteristics:

  • High quantum efficiency, 92%peak@650nm, 83%@232nm
  • High SNR: Ultra-low dark noise under long integration time, SNR is as high as 1000:1
  • Noise-free clear processing of weak signal in long exposure, strong adaption to environment
  • Low-noise and high-speed circuit: USB3.0

 

Typical Applications:

  • Detect absorption, transmittance and reflection Spectrum
  • Light source and laser wavelength characterization
  • OEM product module: Fluorescence spectrum, Raman spectrum, etc.

JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling 0

JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling 1

JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling 2

Company Instroductions:

JINSP – Secure, Certified Spectral Detection Solutions
Trusted by global security and industrial sectors, JINSP Company Limited offers 17 years of expertise in Raman, FT-IR, and LIBS technologies. Our Beijing HQ and Jiangsu plant produce 200+ patented systems, rigorously tested for ECAC, CE, IP Level, and Public Security compliance. When accuracy and certification matter, JINSP delivers.

JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling 3JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling 4JINSP SR100Q Advanced CCD Fiber Optic Spectrometer with High Quantum Efficiency for Ultraviolet Band and TE Cooling 5

FAQ

Q1:This is the first time I use,is it easy to operate?

A1:We will send you manual and guide vedio in English,it can teach you how to operate the spectrometer.Also our technicians will offer professional tecnical opearation meetings.

 

Q2:Can your offer a operation traning?
A2:Your technicians can come to our factory for a training. Jinsp engineers can go to your place for local support
( installation , training, debugging, maintenance ).

 

Q3:What's your website?
A3:You can visit:www.jinsptech.com

 

Q4:What about your quality assurance?

A4:We have a quality inspection team. All goods will go through quality inspection before shipment. We can send you pictures for inspection.

Você pode estar nesses
Entre em contato conosco

Incorpore sua mensagem

phoebeyu@jinsptech.com
+8618620854039
8618620854039
8618620854039