ST830E Optical Coherence Tomography Spectrometer High Resolution Imaging For Medical
Contact Person : Phoebe Yu
Phone Number : 8618620854039
WhatsAPP : +8618620854039
| Minimum Order Quantity : | 1 | Price : | USD20600 - USD22600 |
|---|---|---|---|
| Packaging Details : | International Shipping Package | Delivery Time : | 40-60 WORKING DAYS |
| Payment Terms : | T/T,Western Union | Supply Ability : | 100PCS per 40-60 working days |
| Place of Origin: | CHINA | Brand Name: | JINSP |
|---|---|---|---|
| Certification: | ISO9001 | Model Number: | ST840E-28 |
| Document: | ST840E-28 OCT Spectrometer.pdf |
|
Detail Information |
|||
| Wavelength Range: | 840nm±14nm | Weight: | 2.5 Kg |
|---|---|---|---|
| Model Name: | Optical Coherence Tomography(OCT) Spectrometer | Effective Pixels: | 2048 Pixels |
| Sensing Area: | 20.4*0.2mm | Line Scan Rate: | 130kHz Or 250kHz |
| Highlight: | OCT spectrometer laser welding monitoring,ST840E-28 OCT spectrometer 12.9 mm,OCT spectrometer penetration depth monitoring |
||
Product Description
Weld penetration is the single variable that most directly decides whether a laser-welded joint will survive fatigue loading, pressure testing or crash simulation. Until recently, verifying it meant cutting a coupon, polishing a cross-section and waiting for the metallography laboratory. The JINSP ST840E-28 OCT spectrometer replaces that destructive loop with a non-contact optical measurement that reads the keyhole and the weld root while the laser is still moving.
Built around a 2048-pixel linear CMOS detector and a high-efficiency VPH grating, the ST840E-28 reaches a 12.9 mm imaging depth, which is enough to see the bottom of the keyhole in most production laser welds without repositioning the optics. Axial resolution of 11.2 µm in air resolves the boundary between the fully penetrated zone and the unpenetrated ligament, so an operator sees not only the depth value but also the shape of the root.
A laser weld can look flawless on the surface and still fail because the keyhole collapsed halfway through the sheet stack. Spatter, surface oxidation and clamping variation all change how much energy reaches the interface, and none of these is visible from above. OCT interferometric depth sounding looks through the plasma plume and returns a depth profile that tracks these changes in real time, which makes it possible to reject a part in the same cycle that produced it.
| Parameter | ST840E-28 Specification |
|---|---|
| Model | ST840E-28 series (ST840E1-28 / ST840E2-28) |
| Detector type | Linear CMOS, 2048 pixels |
| Pixel size | 10 × 200 µm |
| Photosensitive area | 20.4 × 0.2 mm |
| Center wavelength | 840 nm |
| Spectral bandwidth | 28 nm |
| Optical resolution | 0.015 nm |
| Imaging depth | 12.9 mm |
| Axial resolution | 11.2 µm in air |
| Max. line scan rate | 130 kHz (USB 3.0) / 250 kHz (CameraLink) |
| Fiber interface | FC/APC |
| ADC bit depth | 8 / 10 / 12 bit |
| Power supply | 11–24 VDC, PoCXP supported |
| Power consumption | < 10 W |
| Dimensions | 312.5 × 166 × 80.5 mm |
| Weight | 2.5 kg |
| Operating temperature | 0°C to 50°C |
The ST840E1-28 pairs the spectrometer with an E2V camera and a USB 3.0 interface at up to 130 kHz line rate, which covers most robotic welding cells and seam-tracking applications. The ST840E2-28 raises the ceiling to 250 kHz over CameraLink for high-speed remote welding, scanner-based wobble welding and cases where the seam moves quickly under the measurement head. Both share the same optical bench, so a process recipe transferred from one to the other keeps the same depth calibration.
The spectrometer exposes an FC/APC fiber input, accepts 11–24 VDC with PoCXP support, draws less than 10 W and weighs 2.5 kg, so it mounts beside an existing welding head without redesigning the cell. JINSP supplies the spectrometer as a module and works with integrators on the sample arm, the trigger synchronisation with the laser controller and the data interface to the customer MES.
Typical installations include automotive body-in-white laser brazing and welding, stainless steel tube and pipe seam welding, appliance panel welding, and general sheet-metal laser welding cells where penetration tolerances are tight and rework is expensive.
![]()
![]()
![]()
JINSP Company Limited has received the National Science and Technology Commission Scientific and Technological Achievement Appraisal Certificate and the China Patent Excellence Award. Related products have earned the Geneva International Invention Award, the Beijing New Technology and New Product Certificate and the Zhu Liangyi Analytical Instrument Innovation Award. JINSP has focused on molecular spectroscopy and OCT spectral detection for more than 19 years and supplies OCT spectrometers, laboratory and online Raman analyzers, and on-site rapid identifiers to industrial customers worldwide. OEM customers receive a dedicated technical contact for the duration of the integration project.
![]()
![]()
Q1: What imaging depth does this OCT spectrometer provide?
A1: The ST840E-28 provides 12.9 mm of imaging depth at 840 nm centre wavelength, which covers the keyhole depth of most laser welding processes in sheet and thin plate.
Q2: Can it measure penetration depth while the laser is welding?
A2: Yes. The spectrometer runs at up to 250 kHz line rate and synchronises with the welding controller so depth data is captured during the process rather than after it.
Q3: What is the difference between the two sub-models?
A3: The ST840E1-28 offers up to 130 kHz over USB 3.0, and the ST840E2-28 offers up to 250 kHz over CameraLink. Both use the same optics and calibration.
Q4: What are the payment terms?
A4: T/T and Western Union, with a minimum order quantity of one unit and delivery in 40–60 working days.