ST830E Optical Coherence Tomography Spectrometer High Resolution Imaging For Medical
Contact Person : Phoebe Yu
Phone Number : 8618620854039
WhatsAPP : +8618620854039
| Minimum Order Quantity : | 1 | Price : | USD20600 - USD22600 |
|---|---|---|---|
| Packaging Details : | International Shipping Package | Delivery Time : | 40-60 WORKING DAYS |
| Payment Terms : | T/T,Western Union | Supply Ability : | 100PCS per 40-60 working days |
| Place of Origin: | CHINA | Brand Name: | JINSP |
|---|---|---|---|
| Certification: | ISO9001 | Model Number: | ST840E-28 |
| Document: | ST840E-28 OCT Spectrometer.pdf |
|
Detail Information |
|||
| Wavelength Range: | 840nm±14nm | Weight: | 2.5 Kg |
|---|---|---|---|
| Model Name: | Optical Coherence Tomography(OCT) Spectrometer | Effective Pixels: | 2048 Pixels |
| Sensing Area: | 20.4*0.2mm | Line Scan Rate: | 130kHz Or 250kHz |
| Highlight: | OCT imaging spectrometer 12.9 mm,OCT spectrometer deep weld inspection,OCT spectrometer penetration inspection |
||
Product Description
Thick-section laser and laser-hybrid welding changes the inspection problem completely. A 10 mm structural steel joint, a pressure-vessel nozzle or a shipbuilding panel does not tolerate a shallow-range optical probe: the measurement has to reach the root, and it has to do so without cutting the part. The ST840E1-28 was specified with the 12.9 mm imaging depth version of the ST840E-28 bench for this class of work.
Cross-sectioning a thick-plate weld costs hours and destroys the joint. Ultrasonic testing finds volumetric defects but struggles to resolve the fusion boundary and cannot report a continuous depth profile along a narrow laser keyhole. OCT sits between the two: optical, non-contact, and quantitative, with 11.2 µm axial resolution that resolves the transition from fused to unfused metal at the root.
For joints deeper than the optical range, JINSP works with customers on double-sided measurement from both faces, or on a sectioned reference sample that correlates OCT depth with metallographic depth, which is the usual route for procedure qualification.
| Parameter | ST840E1-28 |
|---|---|
| Model | ST840E-28 series (ST840E1-28 / ST840E2-28) |
| Detector type | Linear CMOS, 2048 pixels |
| Pixel size | 10 × 200 µm |
| Photosensitive area | 20.4 × 0.2 mm |
| Center wavelength | 840 nm |
| Spectral bandwidth | 28 nm |
| Optical resolution | 0.015 nm |
| Imaging depth | 12.9 mm |
| Axial resolution | 11.2 µm in air |
| Max. line scan rate | 130 kHz (USB 3.0) / 250 kHz (CameraLink) |
| Fiber interface | FC/APC |
| ADC bit depth | 8 / 10 / 12 bit |
| Power supply | 11–24 VDC, PoCXP supported |
| Power consumption | < 10 W |
| Dimensions | 312.5 × 166 × 80.5 mm |
| Weight | 2.5 kg |
| Operating temperature | 0°C to 50°C |
The housing measures 312.5 × 166 × 80.5 mm and weighs 2.5 kg, small enough to mount on the cross-slide of an existing welding gantry or on a linear axis that follows the seam. The unit accepts 11–24 VDC, supports PoCXP, consumes less than 10 W and operates from 0°C to 50°C with humidity below 85% RH, which covers typical fabrication shops without a climate-controlled enclosure.
JINSP supplies the spectrometer with a wavelength calibration file, dispersion coefficients and an SDK, and the application team supports the correlation study against macrosections. Once the correlation curve is established for a given material and joint type, depth readings can be converted directly into a penetration acceptance value for the weld procedure specification.
Heavy fabrication, pressure vessels and heat exchangers, shipbuilding and offshore structures, rail vehicle bodies, and thick-wall tube and pipe production. The same unit is also used for deep drilled-hole depth verification and for measuring the depth of laser-cladded layers.
![]()
![]()
![]()
JINSP Company Limited has received the National Science and Technology Commission Scientific and Technological Achievement Appraisal Certificate and the China Patent Excellence Award. Related products have earned the Geneva International Invention Award, the Beijing New Technology and New Product Certificate and the Zhu Liangyi Analytical Instrument Innovation Award. JINSP has focused on molecular spectroscopy and OCT spectral detection for more than 19 years and supplies OCT spectrometers, laboratory and online Raman analyzers, and on-site rapid identifiers to industrial customers worldwide. OEM customers receive a dedicated technical contact for the duration of the integration project.
![]()
![]()
Q1: Can the sensor inspect every weld on a pack line?
A1: Yes. The acquisition runs per weld at up to 250 kHz line rate, so inspection keeps pace with the welding cell rather than adding a separate station.
Q2: Does it work on copper and aluminium?
A2: Yes. Material-specific gain profiles are applied during reconstruction, and JINSP verifies the calibration on customer samples before delivery.
Q3: What depth range is covered?
A3: 12.9 mm of imaging depth, which covers typical tab, busbar and enclosure welds with margin.
Q4: How do I order?
A4: Contact JINSP with your joint cross-section and takt time. Minimum order quantity is one unit, delivery in 40–60 working days, payment by T/T or Western Union.
Enter Your Message